A tank breathing filter is used to filter the air that enters the tank as it breathes.
At Ultrafilter we have several types of tank breathing filters. From removing moisture to sterilizing the breathing air.
Sterile Tank Breathing Filter P-BE
If you want to maintain sterility in your tank, we offer a P-BE tank filter. The filter consists of a stainless steel housing and a filter element with borosilicate media.
The filter is used to ensure 100% sterility during storage of pharmaceuticals, chemicals, food or ferments.
The two-piece filter housing has a user-friendly design and has "splash protection" that prevents liquids from coming into contact with the filter medium.
Are you unsure whether to choose SS 304 or SS 316? Read our guide here: Guide to stainless steel
Tank Filter is used to ensure 100% sterility in the storage of pharmaceutical products, chemicals, food or fermenerts.
Type | Connection | Filter | Filtration |
P-BE |
DN32 - DN200 |
Dybdefilter |
0,2µm |
Ventfilter |
½" |
Absolutfilter |
0,1 / 0,2 my |
Tank åndingsfilter |
3/4" |
Desicant filter |
Reducere vandindhold |
|
Type P-BE house
|
Capacity at
|
Connection
|
Weight
|
Filter element
|
(Δp = 20 mbar m³/h 1)
|
(Δp = 40 mbar m³/h 1)
|
DN
|
Kg.
|
Size
|
No.
|
0006 |
4,5 |
9 |
DN 32 |
1,5 |
03/10 |
1 |
0027 |
12 |
24 |
DN 40 |
2,2 |
05/25 |
1 |
0032 |
17 |
35 |
DN 50 |
2,4 |
05/30 |
1 |
0072 |
35 |
70 |
DN 50 |
3,3 |
10/30 |
1 |
0144 |
70 |
140 |
DN 80 |
9,2 |
20/30 |
1 |
0192 |
105 |
210 |
DN 80 |
11,6 |
30/30 |
1 |
0432 |
210 |
420 |
DN 100 |
43 |
30/30 |
3 |
0576 |
315 |
630 |
DN 100 |
44 |
30/30 |
3 |
0768 |
420 |
840 |
DN 150 |
70 |
30/30 |
4 |
1152 |
630 |
1260 |
DN 150 |
80 |
30/30 |
6 |
1536 |
840 |
1680 |
DN 200 |
135 |
30/30 |
8 |
1920 |
1050 |
2010 |
DN 200 |
185 |
30/30 |
10 |
P-BE filter
Sterile tank filter is a P-BE filter housing with a P-BE filter element.
The filter is used to ensure 100% sterility during storage of pharmaceuticals, chemicals, food or fermentation.
The two-part filter housing has a user-friendly design and "splash protection" that prevents liquids from coming into contact with the filter media.
P-BE filter element is a wound depth filter having inner and outer shield and end caps made of stainless steel in the 304 option is 316
Vent Filter
Sterile Vent Filter cartridges are designed with a ½ "BSP for autoclave and a small tank ventilation and extraction.
The hydrophobic properties of the ePTFE membrane makes Ventafil filter cartridge particularly suitable for sterilization in an autoclave.
Tank breathingfilter
When you want to empty a container / tank and will want to keep this free of water and water vapor, one may use a tank having åndingsfilter with a filling of decicant capable of removing water from the air.
|
|