Welcome to Ultrafilter webshop, log in or create new accountCustomer Center - Log out

DK NO SE EU

Filter reduction of CO

Omvendt Osmose

New H² two stage filter elements have been specifically developed for high efficient reduction of carbon monoxide as well as some other substances from compressed breathing air.

In first stage Hopcalite catalyst reduces specified substances from the air and in second stage depth fiber filter media intercepts all Hopcalite dust particles.

It is essential that coalescing filter element is installed as pre-filter to the H² grade filter and that relative humidity is sufficiently low.

CO Filter 04/20 (Hopcalit)
CO Filter 04/20 (Hopcalit)
Item no:126624
EUR 127,00EUR 127,00
Qty
 
CO Filter 05/20 (Hopcalit)
CO Filter 05/20 (Hopcalit)
Item no:126632
EUR 146,00EUR 146,00
Qty
 
CO Filter 05/25 (Hopcalit)
CO Filter 05/25 (Hopcalit)
Item no:126640
EUR 368,00EUR 368,00
Qty
 
CO Filter 07/25 (Hopcalit)
CO Filter 07/25 (Hopcalit)
Item no:126648
EUR 457,00EUR 457,00
Qty
 
CO Filter 07/30 (Hopcalit)
CO Filter 07/30 (Hopcalit)
Item no:126656
EUR 657,00EUR 657,00
Qty
 
CO Filter 10/30 (Hopcalit)
CO Filter 10/30 (Hopcalit)
Item no:126664
EUR 924,00EUR 924,00
Qty
 

Sizes
Filter element size Dimensions (mm) Flow capacity Nm3/h Fits into filterhousing3 mbar at Nominal flow Hopcalite (g)
04/20 Ø=51;h=70 78 AG 0012 80 35
05/20 Ø=51;h=140 120 AG 00183 110 135
05/25 Ø=75;h=125 198 AG 0027 120 155
07/25 Ø=75;h=225 335 AG 0036 420 430
07/30 Ø=75;h=325 510 AG 0048 730 740
10/30 Ø=75;h=505 780 AG 0072 1400 1410

Ø = Diameter. h = Height

Differential pressure (mbar) at % of nominal flow
Filter element size 25% 50% 75%3 100%
04/20 20 40 60 80
05/20 28 55 833 110
05/25 30 60 90 120
07/25 105 210 315 420*
07/30 183 365* 548* 730*
10/30 343 685* 1028* 1400*

* It is highly recommended to reduce the flow, so that pressuredrop is below 350 mbar.